Toyota Camry

1996-2001 of release

Repair and operation of the car



Toyota Camry
+ 1. Maintenance instruction
+ 1.2. Information before driving of the car
+ 1.3. Independent maintenance
+ 1.4. Technical characteristics
+ 1.5. Several councils upon purchase of the car
+ 2. Maintenance
- 3. Engines
   + 3.1.2. Check of a compression
   + 3.2. 6-cylinder two-row V6 3,0 engines of l
   + 3.3. Partition of engines
   - 3.4. Engine electric equipment
      3.4.2. Technical characteristics
      3.4.3. Rechargeable battery
      3.4.4. Power cables
      3.4.5. System of ignition
      3.4.6. Coil (i) of ignition
      3.4.7. Check of the moment of ignition
      3.4.8. Block of electronic ignition
      3.4.9. System of a charge of the battery
      3.4.10. Generator
      3.4.11. Regulator of tension and brush
      3.4.12. System of launch of the engine
      3.4.13. Starter electric motor
      3.4.14. Traction relay
      3.4.15. Main malfunctions of electric equipment
      3.4.16. What should be known to the owner of the car with the injector engine
      3.4.17. Turbo doctor
+ 4. Cooling system
+ 5. Heating and ventilation
+ 6. Fuel system
+ 7. Exhaust system
+ 8. Transmission
+ 9. Running gear
+ 10. Brake system
+ 11. Body
+ 12. Electric equipment


3beb1f2e




3.4.10. Generator

GENERAL INFORMATION

Installation of the generator on 4-cylinder engines

1. Adjusting bolt
2. Wire
3. Socket
4. Generator
5. Belt
6. Axial bolt

Installation of the generator on the V6 engine

1. Washer
2. Wire
3. Socket
4. Adjusting bolt
5. Generator
6. Belt
7. Lock bolt
8. Axial bolt

Removal

PERFORMANCE ORDER
1. Disconnect the battery from weight.
2. Disconnect from the wire generator.
3. Weaken axial (And), lock (In) and adjusting (C) bolts of the generator and take off a belt.
4. Turn out adjusting and axial bolts and remove the generator.
5. If you decided to replace the generator, then it must be kept in mind that the new generator has to correspond to accuracy to replaced. Upon purchase track that number on the case of the new unit corresponded to number replaced, and the arrangement of conclusions on both units coincided.

Installation

The generator is installed upside-down.